Product Details:
|
Temperature Range: | -70°C~150°C Or Tailor-made | Test Space: | 25 To 1000Litres |
---|---|---|---|
Electronic: | AC220V·50HZ/380V·50HZ | Meet Test Standard: | IEC, ASTM, MIL, ISO Etc |
Interior Material: | SUS 304 | Refrigeration: | Unit Cooling Mode / Dual Cooling Method (air-cooled)as Per Size Of Chamber And Specific Low Temperature |
High Light: | thermal shock equipment,thermal testing equipment |
Thermal Shock Test Chamber Reduce Risk and Save Cost When Introduce New Product
Thermal shock test reduces the risks which can occur in products due to components or processes and there is less risk involved when a new product or new technology is introduced.During the test, hermal shock causes cracking or faulting along lines of stress as a result from the conflict between uneven element expansion and compression according to relative temperature. Industries such as consumer, medical, automotive, aerospace and construction use thermal shock chamber testing to ensure the reliability of their products.
Two Zone:Hot and Cold zone
Automatic Motorized Lift Up and Down Mechanism
Model | MTS-50 | MTS-100 | MTS-150 | MTS-200 | MTS-300 | |
Interior Volume | 50L | 100L | 150L | 200L | 300L | |
Interior Dimension(cm) | 35*40H*35 | 50*40H*50 | 60*50H*50 | 65*50H*62 | 90*50H*67 | |
Temp Change Rate(with load) | 5℃ ~20℃/m(Standard); 30/℃/m( Liquid Netrogen) | |||||
Hot/Low Temp Range(Testing Zone) | +60℃~+150℃ | -10℃~-65℃ | ||||
Hot/ Low Temp Range(Preheat-precool Zone) | +60℃~+200℃ (Pre heating zone) | 0℃~-78℃ (Pre cooling zone) | ||||
Preheating Time(m) | RT to 150℃ | RT to 150℃ | RT to 150℃ | RT to 150℃ | RT to 150℃ | |
30 | 40 | 40 | 40 | 40 | ||
Precooling Time(m) | -40, -55℃, -65℃ | -40, -55℃, -65℃ | -40, -55℃, -65℃ | -40, -55℃, -65℃ | -40, -55℃, -65℃ | |
70,80,90 | 70,80,90 | 70,80,90 | 70,80,90 | 70,80,90 | ||
Power | (KW) | 20,21,22 | 21,22,23 | 22,23,25 | 28,35,45 | 30,40,50 |
Temp Fluctuation | ±0.5℃ | |||||
Temp Conversion Time | ≤10 seconds | |||||
Temp Recovery Time | ≤5min | |||||
Temp & Humidity Deviation | ±1℃~±2℃ | ±3%RH(>75%RH);±5%RH(≤75%RH) (optional) | ||||
Standard configurations | 1 Window, 1 Cable port, 1 Lamp, 4 Casters, 1 Power cable, 2 Stainless steel shelves | |||||
Standard Documentations | quality certification,test report ,user operaion manual for machine & controller | |||||
Safety devices | Electric leakage, fan overheat ,anti-dry ,compressor overheat & overpressure,power supply undercurrent,overheat, overcurrent, phase sequence, over-temperature protection devices |
Contact Person: Mr. Aiden Zeng
Tel: +86-18929433168