Product Details:
|
Temperature Range: | -70°C~150°C Or Tailor-made | Test Space: | 25 To 1000Litres |
---|---|---|---|
Electronic: | AC220V·50HZ/380V·50HZ | Meet Test Standard: | IEC, ASTM, MIL, ISO Etc |
Interior Material: | SUS 304 | Refrigeration: | Unit Cooling Mode / Dual Cooling Method (air-cooled)as Per Size Of Chamber And Specific Low Temperature |
Product Name: | Thermal Shock Chamber | Temperature Recovery Time: | Within 5min |
High Light: | controlled environment chamber,environmental testing machine |
Basket Transmission Two Zone Hot Cold Thermal Shock Test Chamber
Basket Transmission Two Zone Thermal Shock Chamber is suitable for subjecting products to a thermal shock test by a specimen basket traveling and socking automatically between two pre-heat or pre-cool work zones. As for Air Damper Controlled is called Three Zone Hot Cold Air Stream Thermal Shock Chamber, the specimens under testing were placed in a static test space and stressed by hot or cold air stream which flowed out from two separated air pre-conditioned zones controlled by air dampers.
Working Principle
Three Zone Thermal Shock Chamber means the chamber consist of high temperature zone, low temperature zone, and testing zone. The test sample is in static mode. When doing low temperature testing, cold chamber door open, and low-temperature chamber working together with test chamber.When converted into high-temperature test, cold chamber door closed, hot chamber door are opened, and test chamber working together with high-temperature chamber. Conversion of mechanical action (transferring from high temperature to low temperature or low temperature to high temperature) can be completed in less than 1second, and the temperature can be quickly stabilized.During the whole test, test sample is no need to be moved, and without any human intervention.
While Two Zone Thermal Shock Chamber consist of high temperature zone, low temperature zone only. And the test sample is moving up and down along with the built in air-controlled hanging basket.
Model | MTS-50 | MTS-100 | MTS-150 | MTS-200 | MTS-300 | |
Interior Volume | 50L | 100L | 150L | 200L | 300L | |
Interior Dimension(cm) | 35*40H*35 | 50*40H*50 | 60*50H*50 | 65*50H*62 | 90*50H*67 | |
Temp Change Rate(with load) | 5℃ ~20℃/m(Standard); 30/℃/m( Liquid Netrogen) | |||||
Hot/Low Temp Range(Testing Zone) | +60℃~+150℃ | -10℃~-65℃ | ||||
Hot/ Low Temp Range(Preheat-precool Zone) | +60℃~+200℃ (Pre heating zone) | 0℃~-78℃ (Pre cooling zone) | ||||
Preheating Time(m) | RT to 150℃ | RT to 150℃ | RT to 150℃ | RT to 150℃ | RT to 150℃ | |
30 | 40 | 40 | 40 | 40 | ||
Precooling Time(m) | -40, -55℃, -65℃ | -40, -55℃, -65℃ | -40, -55℃, -65℃ | -40, -55℃, -65℃ | -40, -55℃, -65℃ | |
70,80,90 | 70,80,90 | 70,80,90 | 70,80,90 | 70,80,90 | ||
Power | (KW) | 20,21,22 | 21,22,23 | 22,23,25 | 28,35,45 | 30,40,50 |
Temp Fluctuation | ±0.5℃ | |||||
Temp Conversion Time | ≤10 seconds | |||||
Temp Recovery Time | ≤5min | |||||
Temp & Humidity Deviation | ±1℃~±2℃ | ±3%RH(>75%RH);±5%RH(≤75%RH) (optional) | ||||
Standard configurations | 1 Window, 1 Cable port, 1 Lamp, 4 Casters, 1 Power cable, 2 Stainless steel shelves | |||||
Standard Documentations | quality certification,test report ,user operaion manual for machine & controller | |||||
Safety devices | Electric leakage, fan overheat ,anti-dry ,compressor overheat & overpressure,power supply undercurrent,overheat, overcurrent, phase sequence, over-temperature protection devices |
We have been looking for qualified overseas distributors or dealers to join our business together, and sincerely invite you to visit our company and factory in Dongguan, China. If you are interested in business for environmental chambers and have ability to install, repair test chambers with your professional technician support, please do not hesitate to contact us and join our sales team to establish friendly business relationship based on mutual benefits.
Mentek are Trusteded by World-leading brand and Valuable Clients
Contact Person: Mr. Aiden Zeng
Tel: +86-18929433168